Springs are the clearest case where depth of field, not resolution, decides the optics. A compression spring is a three-dimensional helix: the wire you want to measure at the front of the coil is tens of millimetres nearer the lens than the wire at the back. If both are not within the depth of field, the measurement is of a blurred edge.
For a spring of coil diameter D imaged side-on, the near wire and the far wire are separated by roughly D along the optical axis. A 12 mm coil therefore needs the depth of field to span about 12 mm, or the far wire is out of focus while the near wire is sharp.
Depth of field decreases with magnification and with aperture. This is the direct conflict: the magnification that resolves a 0.02 mm wire tolerance is the magnification that will not hold the coil in focus. The models below are ordered by depth of field for exactly this reason.
| Model | Magnification | Working distance | Resolution | Depth of field | Distortion | Telecentricity | Sensor | Mount |
|---|---|---|---|---|---|---|---|---|
| PMS-LTFM0206-468 | 0.206X | 468mm | 21.16μm | — | <0.01% | <0.02° | 35 mm | F-mount |
| PMS-LTFM024-398 | 0.24X | 398mm | 30.76μm | — | 0.01% | — | 35mm | F-mount |
| PMS-LTCM02-180-G | 0.2X | 180mm | — | — | 0.02% | — | 1″ | C-mount |
| PMS-LMC03-185 | 0.3X | 185mm | — | — | 0.02% | — | 2/3″ | C-mount |
| PMS-LTFM05-179 | 0.5X | 179mm | 18μm | — | — | — | 35mm (72.0×48.0mm) | F-mount |
| PMS-LTCM017-110 | 0.7X | 110±2mm | 16μm | — | 0.01% | <0.01% | — | C-mount |
| PMS-LTCM02-110 | 0.2X | 110mm | 16.78μm | 10mm | 0.02% | — | 2/3″ | C-mount |
| PMS-LTCM023-90 | 0.23X | 90mm | 13.98μm | 7.25mm | 0.02% | — | 2/3″ | C-mount |
| PMS-LTCM03-110-C | 0.3X | 110mm | 11.18μm | 4.44mm | 0.01% | — | 2/3″ | C-mount |
| PMS-LTCM03-110 | 0.3X | 110mm | 11.18μm | 4.4mm | 0.01% | — | 2/3″ | C-mount |
Magnification from 0.2X to 0.8X. Ordered by depth of field, largest first, because on a coiled part the near-to-far wire separation — roughly the coil diameter — has to fit inside it. Note the trade: the models with the highest resolution here are not the ones with the most depth of field.
See when a telecentric lens is the wrong choice.
Stopping down increases depth of field and costs diffraction-limited resolution and light. On springs you almost always stop down, because a sharp image of half the coil is less useful than an adequate image of the whole coil. The practical consequence is that spring stations need more illumination than the same magnification would on a flat part.
Springs roll. A spring resting on a flat plate contacts at two wire points and its axis is rarely parallel to the sensor. A V-block or a locating pin through the bore makes the presentation repeatable, and repeatable presentation is what makes free length measurable at all. On very small springs, hanging the part from a pin avoids contact deformation entirely.
Backlight for the silhouette. Springs are usually metallic and curved, so a collimated backlight matters: with a diffuse backlight the curved wire edges produce a gradient rather than a step, and the extracted edge position then drifts with threshold. The lighting guide covers this.
Because the far wire is outside the depth of field and therefore blurred, and a blurred silhouette edge reads wider. The error is systematic rather than random, which makes it easy to mistake for a genuine dimensional trend. Measure the near wire, or increase depth of field by stopping down.
Only if the bore is actually visible through the coil. On tightly wound springs the near wire occludes it, and the inner boundary of the silhouette is the wire, not the bore.
Start from depth of field, not resolution. The near and far wires are separated by roughly the coil diameter along the optical axis, so the depth of field has to cover that first; magnification and aperture then follow, and resolution is what is left over.
Usually yes. A sharp image of half the coil is less useful than an adequate image of the whole coil. The cost is diffraction-limited resolution and light, so plan for more illumination than the same magnification would need on a flat part.
Yes, it is the most robust spring measurement — a two-edge distance. The prerequisite is repeatable presentation: springs roll, and a part resting on a flat plate rarely has its axis parallel to the sensor. Use a V-block or a locating pin.
Only when the far side of the coil is not occluded by the near side. On tightly wound springs it usually is, and the count has to come from a different view or from the manufacturing record.
Specification arithmetic gets you to a shortlist, not to a verdict. Send one part with the drawing and the tolerance you have to hold, and we will run it and report what the system returns — including the features that come back as unmeasurable. A written feasibility note is worth more than another datasheet.
Simply enter your email to receive the latest news and insights from Pomeas. Stay connected with Pomeas and be the first to discover new innovations in optical excellence.